Nominal size: 130 mm (4.5")
Approval: Gost
For corrosive gases and liquids
With or without damping fluid
Main Features
Application
| Technical Data | |
|---|---|
| Nominal Size | 100 mm |
| Measurement range | MEP : -1 ... 0 to 0 ... 1600 bar MMN : -1 ... 0 to 0 ... 600 bar |
| Accuracy | Class 1 (according EN837-1) |
| Pressure limitation : Ranges ≤ 600 bar | Steady : 100% of full scale value Fluctuating : 90% of full scale value Short time : 130% of full scale value |
| Pressure limitation : Ranges > 600 bar | Steady : 75% of full scale value Fluctuating : 65% of full scale value Short time : 100% of full scale value |
| Process Connection | Stainless steel 1.4404 (AISI 316L) |
| Bourdon tube | Stainless steel 1.4404 (AISI 316L) |
Certification
Approvals Certification Material certificate 3.1 EN10204 / Calibration certificate EN837-1
(5 points raising and 5 points falling)